Nuair a dhéantar an teagmhálaí AC a fhuinneamh, gineann an corna inmheánach réimse maighnéadach, rud a mheallann an croí iarainn atá ag gluaiseacht agus an croí iarainn seasta a chéile. Tiomáineann an ghluaiseacht seo an córas teagmhála chun dul i ngleic leis na teagmhálacha seasta, ag comhlánú an chuaird. Nuair a dhéantar an coil a dhí-fhuinneamh, imíonn an fórsa tarraingthe, agus ardaíonn an t-earrach athshocraithe an croí iarainn atá ag gluaiseacht, ag scaradh na dteagmhálacha agus ag briseadh an chiorcaid.
| |
| |
| |
| Cumhacht uasta an mhótair leictreach AC 0≤55°C, 400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 |
| Múnla táirge (léaráid líne AC) | AX09 | AX12 | AX18 | AX25 | AX32 | AX40 | AX50 | AX65 | AX80 |
| Rátáilte sruth oibre AC-3 0≤55°C, 400V | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 |
| Rátáilte sruth oibre AC-1 0≤55°C, 400V | 22 | 25 | 27 | 32 | 55 | 60 | 100 | 115 | 125 |
| Cineál Múnla | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 | |
| sruth oibre rátáilte (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
| Mótar trí phas Leibhéal AC-3 (kw) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
| 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | - | - | |
| 500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | - | - | |
| 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 | |
| srutha teasa rátáilte(A) | 20 | 20 | 30 | 32 | 40 | 50 | 60 | 80 | 125 | 125 | |
| Saolré leictreach (10000 timthriall) | AC3 | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
| AC4 | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
| saolré meicniúil (10000 timthriall) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
| Múnla teagmhála | 3P UIMH | 3P NC UIMH | |||||||||
| Múnla | Reatha rátáilte (A) | Príomhtheagmhálaí | Teagmháil chúnta | Cumhacht ualaigh aon phas (kW) | Cumhacht ualaigh trí phas (kW) |
| CJX2-0910 | 9A | 3 NÍL | 1NÍL | 1.8KW | 3.5KW |
| CJX2-0901 | 9A | 3 NÍL | 1NC | 1.8KW | 3.5KW |
| CJX2-1210 | 12A | 3 NÍL | 1NÍL | 2.5KW | 5KW |
| CJX2-1201 | 12A | 3 NÍL | 1NC | 2.5KW | 5KW |
| CJX2-1810 | 18A | 3 NÍL | 1NÍL | 3.5KW | 7.5KW |
| CJX2-1801 | 18A | 3 NÍL | 1NC | 3.5KW | 7.5KW |
| CJX2-2510 | 25A | 3 NÍL | 1NÍL | 5KW | 8.5KW |
| CJX2-2501 | 25A | 3 NÍL | 1NC | 5KW | 8.5KW |
| CJX2-3210 | 32A | 3 NÍL | 1NÍL | 6KW | 12KW |
| CJX2-3201 | 32A | 3 NÍL | 1NC | 6KW | 12KW |
| CJX2-4011 | 40A | 3 NÍL | 1NÍL 1NC | 8KW | 18.5KW |
| CJX2-5011 | 50A | 3 NÍL | 1NÍL 1NC | 10KW | 24KW |
| CJX2-6511 | 65A | 3 NÍL | 1NÍL 1NC | 12.5KW | 28KW |
| CJX2-8011 | 80A | 3 NÍL | 1NÍL 1NC | 15.5KW | 37KW |
| CJX2-9511 | 95A | 3 NÍL | 1NÍL 1NC | 18.5KW | 44KW |